Replacement |
1. |
Loosen the wheel nuts slightly. Raise the vehicle, and make sure it is securely supported. |
2. |
Remove the rear wheel and tire (A) from rear hub.
|
3. |
Remove the brake caliper mounting bolts , and then hold the brake caliper assembly (B) with wire.
|
4. |
Remove the wheel speed sensor (A), from the knuckle.
|
5. |
Remove castle nut (A) from the rear hub.
|
6. |
Remove the rear brake lining assembly (A).(Refer to BR group - Parking brake system) |
7. |
Remove the parking brake cable (B) from the brake shoe (A). |
8. |
Remove the parking brake cable retaining (B), from the parking brake cable (A). |
9. |
Remove the assist arm (A) from the rear axle carrier.
|
10. |
Remove the trailing arm (B) from the rear axle carrier.
|
11. |
Remove the upper arm (A) from the rear axle carrier.
|
12. |
Push the rear axle carrier outward and separate the driveshaft (A) from the axle hub . |
13. |
Remove the lower arm (A) from the rear axle carrier(B).
|
14. |
Install in the reverse order of removal.
|
Inspection |
1. |
Check the hub for cracks and the splines for wear. |
2. |
Check the brake disc for scoring and damage. |
3. |
Check the rear axle carrier for cracks |
4. |
Check the bearing for cracks or damage. |
Disassembly |
1. |
Remove the hub assembly form the near knuckle assembly.
|
2. |
Using the snap ring pliers, remove the snap ring (A). |
3. |
Remove the hub bearing outer race form the hub assembly.
|
4. |
Replace hub bearing with a new one. |
Reassembly |
1. |
Install the hub bearing to the knuckle assembly.
|
2. |
Install the hub assembly to the knuckle assembly.
|
3. |
Install the snap ring (A). |
Transaxle Oil Temperature Sensor: Description and Operation
Description
Transaxle oil temperature sensor monitors the automatic
transaxle fluid''s temperature and conveys the readings to TCM. It is an
NTC (Negative Thermal Coefficient) sensor whose resi ...
Specifications
Specification
Air Conditioner
ItemSpecificationCompressorTypeDVE16Oil type & CapacityPAG OIL 120±10Pulley type6PK-TYPEDisplacement160cc/revCondenserHeat rejection14,000 ±5% kcal/hrA/C Pressu ...