Inspection |
1. |
Remove the fuse box cover. |
2. |
Remove the starter relay (A). |
3. |
Using an ohmmeter, check that there is continuity between each terminal.
|
4. |
Apply 12V to terminal 85 and ground to terminal 86.
Check for continuity between terminals 30 and 87. |
5. |
If there is no continuity, replace the starter relay. |
6. |
Install the starter relay. |
7. |
Install the fuse box cover. |
Pressure Sensor: Repair procedures
Inspection
If you have trouble code related to the pressure sensor
(P1825, P1826, P1827, P1828), check pressure sensor according to the
inspection process.
Pre ...
Heated Oxygen Sensor (HO2S): Description and Operation
Description
Heated Oxygen Sensor (HO2S) consists of zirconium and alumina
and is installed both upstream and downstream of the Manifold Catalytic
Converter. The sensor output voltage varies in ...