Inspection |
1. |
Turn ignition switch OFF. |
2. |
Remove the air duct (A). |
3. |
Remove the air cleaner assembly.
|
4. |
Disconnect the solenoid valve connector (A). |
5. |
Measure resistance between sensor signal terminal and ground terminal. |
6. |
Check that the resistance is within the specification. |
Removal |
Replacing an on/off solenoid valve (SS-A, SS-B) does not
require additional hydraulic pressure adjustment; however, the hydraulic
pressure will need to be adjusted after replacing the VFS solenoid
valve. If replacing the VFS solenoid valve; also replace the valve body
assembly.
(Refer to "Valve Body" in Hydraulic System of this group) |
Accelerator Position Sensor (APS): Description and Operation
Description
Accelerator Position Sensor (APS) is installed on the
accelerator pedal module and detects the rotation angle of the
accelerator pedal. The APS is one of the most important sensors ...
Torque Converter Control Solenoid Valve (T/CON_VFS): Description and Operation
Description
Torque converter control solenoid valve (T/CON_VFS) is
attached to the valve body. This variable force solenoid valve directly
controls the hydraulic pressure inside the torque conv ...