Specification |
Throttle Angle(°) | Output Voltage(V) [Vref = 5.0V] | |
TPS1 | TPS2 | |
0 | 0.0 | 5.0 |
10 | 0.48 | 4.52 |
20 | 0.95 | 4.05 |
30 | 1.43 | 3.57 |
40 | 1.90 | 3.10 |
50 | 2.38 | 2.62 |
60 | 2.86 | 2.14 |
70 | 3.33 | 1.67 |
80 | 3.81 | 1.19 |
90 | 4.29 | 0.71 |
100 | 4.76 | 0.24 |
105 | 5.0 | 0 |
Item | C.T | W.O.T | |
TPS1 | Throttle Angle (°) | 6.3 ~ 14.7 | 93.45 ~ 101.85 |
Output Voltage [Vref=5V] | 0.3 ~ 0.7 | 4.45 ~ 4.85 | |
TPS2 | Throttle Angle (°) | 90.3 ~ 98.7 | 3.15 ~ 11.55 |
Output Voltage [Vref=5V] | 4.3 ~4.7 | 0.15 ~ 0.55 |
Item | Sensor Resistance(k?) |
TPS | 0.875 ~ 1.625 [20°C(68°F)] |
Item | Specification |
Coil Resistance (?) | 1.2 ~ 1.8 [20°C(68°F)] |
Troubleshooting
Troubleshooting
Problem Symptoms Table
Before replacing or repairing air conditioning components,
first determine if the malfunction is due to the refrigerant charge, air
flow or compressor. ...
Cluster ionizer: Repair procedures
Inspection
1.
Press the OFF switch more then 4 times within 2 seconds while pressing the MODE switch.
DisplayFail description00Normal50Cluster ionizer fault