Components |
1. Cooling fan assembly 2. Radiator assembly 3. Mounting insulator 4. Radiator mounting bracket 5. Radiator upper hose | 6. Radiator lower hose 7. Reservoir tank 8. Over flow hose 9. ATF cooler hoses |
Purge Control Solenoid Valve (PCSV): Repair procedures
Inspection
1.
Turn the ignition switch OFF.
2.
Disconnect the PCSV connector.
3.
Measure resistance between the PCSV terminals 1 and 2.
4.
Check that the resistance is within the speci ...
Direct Electro Hydraulic Actuator Coupling: Repair procedures
Inspection
All units are filled up with coupling fluid (ultra-low
viscosity ATF) prior to shipping. Inspection, fill-up, and replacement
of coupling fluid is theref ...