Troubleshooting |
Symptom | Possible cause | Remedy |
One lamp does not light (all exterior) | Bulb burned out | Replace bulb |
Socket, wiring or ground faulty | Repair if necessary | |
Head lamps do not light | Bulb burned out | Replace bulb |
Ignition fuse (LOW:10A, HIGH:20A) blown | Check for short and replace fuse | |
Head lamp fuse (15A) blown | Check for short and replace fuse | |
Head lamp relay faulty | Check relay | |
Lighting switch faulty | Check switch | |
Wiring or ground faulty | Repair if necessary | |
Tail lamps and license plate lamps do not light | Bulb burned out | Replace bulb |
Tail lamp fuse (10A) blown | Check for short and replace fuse | |
Tail lamp relay faulty | Check relay | |
Lighting switch faulty | Check switch | |
Wiring or ground faulty | Repair if necessary | |
Stop lamps do not light | Bulb burned out | Replace bulb |
Stop lamp fuse (15A) blown | Check for short and replace fuse | |
Stop lamp switch faulty | Adjust or replace switch | |
Wiring or ground faulty | Repair if necessary | |
Stop lamps do not turn off | Stop lamp switch faulty | Repair or replace switch |
Instrument lamps do not light (Tail lamps light) | Rheostat faulty | Check rheostat |
Wiring or ground faulty | Repair if necessary | |
Turn signal lamp does not flash on one side | Bulb burned out | Replace bulb |
Turn signal switch faulty | Check switch | |
Wiring or ground faulty | Repair if necessary | |
Turn signal lamps do not light | Bulb burned out | Replace bulb |
Turn signal lamp fuse (10A) blown | Check for short and replace fuse | |
Flasher unit faulty | Check flasher unit | |
Turn signal switch faulty | Check switch | |
Wiring or ground faulty | Repair if necessary | |
Hazard warning lamps do not light | Bulb burned out | Replace bulb |
Hazard warning lamp fuse (15A) blown | Check for short and replace fuse | |
Flasher unit faulty | Check flasher unit | |
Hazard switch faulty | Check switch | |
Wiring or ground faulty | Repair if necessary | |
Flasher rate too slow or too fast | Lamps'' wattages are smaller or larger than specified | Replace lamps |
Flasher unit faulty | Check flasher unit | |
Back up lamps do not light | Bulb burned out | Replace bulb |
Back up lamp fuse (10A) blown | Check for short and replace fuse | |
Back up lamp switch (M/T) faulty | Check switch | |
Transaxle range switch (A/T) faulty | Check switch | |
Wiring or ground faulty | Repair if necessary | |
Room lamp does not light | Bulb burned out | Replace bulb |
Room lamp fuse (10A) blown | Check for short and replace fuse | |
Room lamp switch faulty | Check switch | |
Wiring or ground faulty | Repair if necessary | |
Front fog lamps do not light | Bulb burned out | Replace bulb |
Front fog lamp fuse (15A) blown | Check for short and replace fuse | |
Front fog lamp relay faulty | Check relay | |
Front fog lamp switch faulty | Check switch | |
Wiring or ground faulty | Repair if necessary | |
Rear fog lamps do not light | Rear fog lamp fuse (15A) blown | Check for short and replace fuse |
Rear fog lamp fuse (15A) blown | Check for short and replace fuse | |
Rear fog lamp switch faulty | Check switch | |
Rear fog lamp relay faulty | Check relay | |
Wiring or ground faulty | Repair if necessary | |
Map lamp does not light | Bulb burned out | Replace bulb |
Room lamp fuse (10A) blown | Check for short and replace fuse | |
Map lamp switch faulty | Check switch | |
Wiring or ground faulty | Repair if necessary | |
Trunk room lamp does not light | Bulb burned out | Replace bulb |
Room lamp fuse (10A) blown | Check for short and replace fuse | |
Trunk room lamp switch faulty | Check switch | |
Wiring or ground faulty | Repair if necessary |
Side Impact Sensor (SIS): Repair procedures
Removal
Pressure Side Impact Sensor
•
Removal of the airbag must be performed according to the precautions/procedures described previously.
•
Before ...
Checking the amount of air conditioner refrigerant and compressor lubricant
When the amount of refrigerant is low, the performance of the air conditioning
is reduced. Overfilling also has a negative impact on the air conditioning system.
Therefore, if abnormal operation is ...