Specification |
Item | Specification | |
Compressor | Type | DVE16 |
Oil type & Capacity | PAG OIL 120±10 | |
Pulley type | 6PK-TYPE | |
Displacement | 160cc/rev | |
Condenser | Heat rejection | 14,000 ±5% kcal/hr |
A/C Pressure transducer | The method to measure the pressure | Voltage= 0.00878835 * Pressure (psig) + 0.5 |
Expansion valve | Type | Block type |
Refrigerant | Type | R-134a |
Capacity [g.(oz)] | 550±25 (19.4±0.88) |
Item | Specification | |
Fresh and recirculation | Operating method | Actuator |
Blower | Type | Sirocco |
Speed step | Auto + 8 speed (Automatic), 1~4speed (Manual) | |
Speed control | Power mosfet (Auto), Resistor(manual) | |
Air filter | Type | Particle filter |
Item | Specification | |
Heater | Type | Pin & Tube type |
Heating capacity | 4,600 - 5% kcal/hr | |
Mode operating method | Actuator | |
Temperature operating method | Actuator | |
Evaporator | Temperature control type | Evaporator temperature sensor |
A/C ON/OFF [°C(°F)] | ON : 1.5 ± 0.5 (34.7 ± 32.9) OFF: -0.5 ± 0.5 (32.9 ± 32.9) |
Front Fog Lamps: Repair procedures
Inspection
Front Fog Lamp Switch
1.
With the fog lamp switch in each position, make sure that
continuity exists between the terminals below. If continuity is not as
specified, replace the mul ...
ON
Green indicator
• With automatic transaxle
Press the ENGINE START/STOP button while it is in the ACC position without depressing
the brake pedal.
The warning lights can be checked before the en ...