Inspection |
1. |
Turn ignition switch OFF. |
2. |
Remove the air duct (A). |
3. |
Remove the air cleaner assembly.
|
4. |
Disconnect the solenoid valve connector (A). |
5. |
Measure resistance between sensor signal terminal and ground terminal. |
6. |
Check that the resistance is within the specification. |
Removal |
Replacing an on/off solenoid valve (SS-A, SS-B) does not
require additional hydraulic pressure adjustment; however, the hydraulic
pressure will need to be adjusted after replacing the VFS solenoid
valve. If replacing the VFS solenoid valve; also replace the valve body
assembly.
(Refer to "Valve Body" in Hydraulic System of this group) |
Cluster ionizer: Repair procedures
Inspection
1.
Press the OFF switch more then 4 times within 2 seconds while pressing the MODE switch.
DisplayFail description00Normal50Cluster ionizer fault
* Diagnostic procedure refer to ...
Description and Operation
Warning Lamp Activation
Warning Lamp Behavior after Ignition On
As soon as the operating voltage is applied to the SRSCM
ignition input, the SRSCM activates the warning lamp for a LED lamp
c ...