Kia Sportage: Specifications| Specification |
| Item | Specification | |
| Compressor | Type | DVE16 |
| Oil type & Capacity | PAG OIL 120±10 | |
| Pulley type | 6PK-TYPE | |
| Displacement | 160cc/rev | |
| Condenser | Heat rejection | 14,000 ±5% kcal/hr |
| A/C Pressure transducer | The method to measure the pressure | Voltage= 0.00878835 * Pressure (psig) + 0.5 |
| Expansion valve | Type | Block type |
| Refrigerant | Type | R-134a |
| Capacity [g.(oz)] | 550±25 (19.4±0.88) | |
| Item | Specification | |
| Fresh and recirculation | Operating method | Actuator |
| Blower | Type | Sirocco |
| Speed step | Auto + 8 speed (Automatic), 1~4speed (Manual) | |
| Speed control | Power mosfet (Auto), Resistor(manual) | |
| Air filter | Type | Particle filter |
| Item | Specification | |
| Heater | Type | Pin & Tube type |
| Heating capacity | 4,600 - 5% kcal/hr | |
| Mode operating method | Actuator | |
| Temperature operating method | Actuator | |
| Evaporator | Temperature control type | Evaporator temperature sensor |
| A/C ON/OFF [°C(°F)] | ON : 1.5 ± 0.5 (34.7 ± 32.9) OFF: -0.5 ± 0.5 (32.9 ± 32.9) | |
TroubleshootingTemperature control
The temperature will increase to the maximum (HI) by turning the knob to the
extreme right.
The temperature will decrease to the minimum (Lo) by turning the knob to the
extreme left.
When turn ...
Compressor: Repair procedures
Removal
1.
If the compressor is marginally operable, run the engine at
idle speed, and let the air conditioning work for a few minutes, then
shut the engine off.
2.