Kia Sportage: Specifications
Air Conditioner
Item
| Specification
|
Compressor
| Type
| DVE16
|
Oil type & Capacity
| PAG OIL 120±10
|
Pulley type
| 6PK-TYPE
|
Displacement
| 160cc/rev
|
Condenser
| Heat rejection
| 14,000 ±5% kcal/hr
|
A/C Pressure transducer
| The method to measure the pressure
| Voltage= 0.00878835 * Pressure (psig) + 0.5
|
Expansion valve
| Type
| Block type
|
Refrigerant
| Type
| R-134a
|
Capacity [g.(oz)]
| 550±25 (19.4±0.88)
|
Blower Unit
Item
| Specification
|
Fresh and recirculation
| Operating method
| Actuator
|
Blower
| Type
| Sirocco
|
Speed step
| Auto + 8 speed (Automatic), 1~4speed (Manual)
|
Speed control
| Power mosfet (Auto), Resistor(manual)
|
Air filter
| Type
| Particle filter
|
Heater And Evaporator Unit
Item
| Specification
|
Heater
| Type
| Pin & Tube type
|
Heating capacity
| 4,600 - 5% kcal/hr
|
Mode operating method
| Actuator
|
Temperature operating method
| Actuator
|
Evaporator
| Temperature control type
| Evaporator temperature sensor
|
A/C ON/OFF [°C(°F)]
| ON : 1.5 ± 0.5 (34.7 ± 32.9) OFF: -0.5 ± 0.5 (32.9 ± 32.9)
|
Troubleshooting
Problem Symptoms Table
Before replacing or repairing air conditioning components,
first determine if the malfunction is due to the refrigerant charge, air
flow or compressor. ...
Other Information:
PDM Relay Box: Description and Operation
Description
The PDM relay (A) is united with IG1, IG2 and ACC relays and installed in the lower center fascia panel. ...
Troubleshooting
Basic Troubleshooting
Basic Troubleshooting Guide
Customer Problem Analysis Sheet
Basic Inspection Procedure
Measuring Condition of Electronic Parts'' Resistance
The measured resistance at high ...