Air Conditioner
Item
| Specification
|
Compressor
| Type
| DVE16
|
Oil type & Capacity
| PAG OIL 120±10
|
Pulley type
| 6PK-TYPE
|
Displacement
| 160cc/rev
|
Condenser
| Heat rejection
| 14,000 ±5% kcal/hr
|
A/C Pressure transducer
| The method to measure the pressure
| Voltage= 0.00878835 * Pressure (psig) + 0.5
|
Expansion valve
| Type
| Block type
|
Refrigerant
| Type
| R-134a
|
Capacity [g.(oz)]
| 550±25 (19.4±0.88)
|
Blower Unit
Item
| Specification
|
Fresh and recirculation
| Operating method
| Actuator
|
Blower
| Type
| Sirocco
|
Speed step
| Auto + 8 speed (Automatic), 1~4speed (Manual)
|
Speed control
| Power mosfet (Auto), Resistor(manual)
|
Air filter
| Type
| Particle filter
|
Heater And Evaporator Unit
Item
| Specification
|
Heater
| Type
| Pin & Tube type
|
Heating capacity
| 4,600 - 5% kcal/hr
|
Mode operating method
| Actuator
|
Temperature operating method
| Actuator
|
Evaporator
| Temperature control type
| Evaporator temperature sensor
|
A/C ON/OFF [°C(°F)]
| ON : 1.5 ± 0.5 (34.7 ± 32.9) OFF: -0.5 ± 0.5 (32.9 ± 32.9)
|
Troubleshooting
Problem Symptoms Table
Before replacing or repairing air conditioning components,
first determine if the malfunction is due to the refrigerant charge, air
flow or compressor. ...
Other Information:
SRS Control Module (SRSCM): Description and Operation
Description
The primary purpose of the SRSCM (Supplemental Restraints
System Control Module) is to discriminate between an event that warrants
restraint system deployment and an event that does ...
Winter driving
Severe weather conditions in the winter result in greater wear and other problems.
To minimize the problems of winter driving, you should follow these suggestions: ...