Specifications |
Item | Requirement | Remark |
Rated voltage | DC 12V | |
Operating voltage range | DC 9 ~ 16V | Shall activate normally in these range |
Operating temperature range | -30°C ~ +80°C | Shall conserve normally in these range. |
Storage temperature range | -40°C ~ +85°C | |
Max humidity in use | 95% | |
High voltage resistance | 24V/1min, 18V/1hour | After overvoltage is the Normal behavior |
Insulation resistance | 100M? or more (measured with 500V MEGGER) | Specify as well as parts that insulation like PCB, moisture-proof COATING is required. |
Quiescent current | KEYLESS spec : 6mA or less SMK spec : 5.5mA or less NON-KEYLESS : 4mA or less | Measure when the state, all output loads are OFF and there are no Input SW(including TX operation) changes, continues 2sec. |
Voltage drop | 1.2V or less | but, Terminal B9, B20, C1, C2, C3, C13, C14, C15, C16 is 2.0V or less. |
Troubleshooting
Troubleshooting
Customer Complaint Analysis Check Sheet
There are six areas where a problem can occur: wiring
harness, the radio, the CD player, and speaker. Troubleshooting enables
you to con ...
Torque Converter Control Solenoid Valve (T/CON_VFS): Repair procedures
Inspection
1.
Turn ignition switch OFF.
2.
Remove the air duct (A).
3.
Remove the air cleaner assembly.
(1)
Disconnect the breather hose (A) and brake booster intensifier hose.
(2)
...