1.Turn the ignition switch to the ON position.
2.Turn the mode selection knob to the defrost position ().
3.Press the air intake control button at least 5 times within 3 seconds.
The indicator light in the air intake control button will blink 3 times with 0.5 second of interval. It indicates that the defogging logic is canceled or returned to the programmed status.
If the battery has been discharged or disconnected, it resets to the defog logic status.
Ambient Sensor: Description and Operation
Description
1.
The ambient temperature sensor is located at the front of the
condenser and detects ambient air temperature. It is a negative type
thermistor; resistance will increase with lowe ...
Output Speed Sensor: Description and Operation
Description
The Output Speed Sensor is a vital unit that measures the
rate of rotation of the transmission''s turbine shaft and output shaft,
and delivers the readings to the TCM. ...