Kia Sportage: Coupling Assembly
4WD ECU: Repair procedures
Direct Electro Hydraulic Actuator Coupling: Description and OperationRCV Control Solenoid Valve: Description and Operation
Description
RCV (Recirculation Valve) Control Solenoid Valve is installed
on the intercooler inlet pipe and operates the RCV actuator which
controls the by-pass passage of the turbocharger comp ...
Air intake control
The air intake control is used to select the outside (fresh) air position or
recirculated air position.
To change the air intake control position, press the control button.
Recirculated air posi ...